CO2 vs A2L Refrigerants: The Future of Refrigeration
Compare CO2 and A2L refrigerants for industrial cooling. Learn about eco-friendliness, efficiency, safety, and regulations to choose the best solution for your business.

Refrigerant selection has become a central issue in refrigeration system design as environmental regulations increasingly target substances with high global warming potential (GWP). Owners, engineers, and contractors are now evaluating alternatives that reduce environmental impact while maintaining safety, reliability, and long-term viability.
Two refrigerant categories frequently discussed are carbon dioxide (CO₂ / R744) and A2L-classified synthetic refrigerants. Although both are often described as “low-GWP options,” they differ significantly in system design, safety classification, regulatory treatment, and typical application range. Understanding these differences is essential—particularly when comparing industrial refrigeration systems with HVAC and light commercial applications.
Understanding Global Warming Potential (GWP)
Global Warming Potential (GWP) is a metric that compares how much heat a greenhouse gas traps in the atmosphere relative to carbon dioxide over a specified time horizon, typically 100 years. Carbon dioxide is assigned a baseline GWP of 1.
- Refrigerants with higher GWP values contribute more significantly to climate change if released.
- Regulatory frameworks increasingly restrict or phase down refrigerants with elevated GWP, making this metric a key consideration in refrigerant selection.
CO₂ (R744) as a Refrigerant
General Characteristics
Carbon dioxide is a naturally occurring refrigerant with a GWP of 1. It is classified as A1, meaning it is non-flammable and non-toxic under normal operating conditions. These properties have contributed to its growing use in commercial and industrial refrigeration where long-term regulatory certainty and safety classification are important considerations.
CO₂ systems commonly operate in transcritical mode, particularly in warmer ambient conditions. This results in operating pressures significantly higher than those seen in traditional HFC systems and requires components specifically designed for those pressures.
Applications
CO₂ refrigeration has been widely adopted in:
- Supermarkets
- Cold storage facilities
- Food processing and distribution centers
In industrial and large commercial systems, CO₂ is often selected where owners wish to avoid both toxic refrigerants and flammable classifications.
Advantages of CO₂ Systems
- Low environmental impact: GWP of 1 minimizes direct climate impact from refrigerant release.
- Non-flammable classification: Avoids fire-related code and risk concerns associated with flammable refrigerants.
- Regulatory durability: CO₂ is generally viewed as less exposed to future phase-down initiatives compared to synthetic refrigerants.
- Established industrial use: Increasing number of documented installations in cold storage and food-related industries.
Challenges and Limitations
- High operating pressures: Require specialized equipment, materials, and safety design.
- System complexity: Installation and service demand technicians trained specifically in CO₂ systems.
- Climate sensitivity: Efficiency can decline in high ambient temperatures during transcritical operation, although modern system architectures (e.g., parallel compression, ejectors) can mitigate this effect.
- Maintenance practices: CO₂ systems differ from conventional HFC systems in leak response and service procedures, requiring appropriate planning and expertise.
A2L Refrigerants
Definition and Classification
A2L refrigerants are synthetic refrigerants classified as non-toxic and mildly flammable. They are designed primarily as lower-GWP alternatives to traditional HFCs and HCFCs. Individual A2L refrigerants vary in composition and properties, but they generally offer substantially lower GWP than legacy HFC refrigerants.
Typical Applications
A2L refrigerants are most commonly applied in:
- Residential HVAC
- Commercial HVAC
- Light commercial refrigeration
Their adoption in large industrial refrigeration systems is currently limited and subject to evolving codes, standards, and jurisdictional acceptance.
Advantages of A2L Refrigerants
- Reduced GWP compared to traditional HFCs: Supports compliance with current phase-down regulations.
- Compatibility with modern HVAC equipment designs: Often used in newly designed systems rather than retrofits.
- Potential efficiency benefits: Performance depends heavily on system design and operating conditions and should be evaluated on a case-by-case basis.
Challenges and Limitations
- Mild flammability: Requires compliance with updated safety standards, including leak detection, ventilation, and charge limitations.
- Code and jurisdictional constraints: Use in larger systems may be restricted or subject to additional requirements depending on location.
- Limited industrial track record: Compared to CO₂ and ammonia, A2Ls have less established history in large-scale industrial refrigeration.
- System-specific design requirements: A2Ls cannot be directly substituted into A1-rated systems without redesign and component changes.
Regulatory Considerations
Refrigerant regulations continue to evolve at both national and international levels. Current trends emphasize the reduction of high-GWP substances, but implementation varies by region and application type.
- Canada: Federal regulations focus on phasing down high-GWP HFCs and controlling refrigerant management practices.
- United States: The AIM Act mandates a long-term reduction in HFC production and consumption, influencing refrigerant selection.
- European Union: F-Gas regulations impose quotas and restrictions that favor lower-GWP alternatives, including CO₂ and certain A2L refrigerants.
It is important to note that no refrigerant should be considered entirely “future-proof.” Regulatory treatment depends on policy decisions, safety standards, and practical deployment experience.
Common Misconceptions
“High pressure makes CO₂ systems unsafe”
CO₂ systems operate at higher pressures than traditional refrigerants, but modern designs incorporate pressure-rated components and safety devices intended to manage these conditions when properly engineered and maintained.
“A2Ls are unsafe due to flammability”
A2L refrigerants are classified as mildly flammable, not highly flammable. When systems are designed and installed in accordance with applicable codes and standards, risks can be managed. However, flammability remains a design and regulatory consideration.
“CO₂ and A2Ls are interchangeable”
CO₂ and A2L refrigerants serve different application niches. CO₂ is commonly applied in large commercial and industrial systems, while A2Ls are primarily deployed in HVAC and light commercial refrigeration.
Choosing the Appropriate Refrigerant
Refrigerant selection should consider:
- Application type (industrial, commercial, HVAC)
- System size and refrigerant charge
- Local codes and regulatory requirements
- Safety classification and risk tolerance
- Availability of trained service personnel
- Long-term operational and compliance considerations
In many cases, CO₂ and A2L refrigerants are not direct competitors but tools suited to different system scales and objectives.
Application-Driven Considerations for CO₂ and A2L Refrigerants
CO₂ and A2L refrigerants both play important roles in the transition away from high-GWP refrigerants, but they are best understood as complementary technologies rather than interchangeable solutions. CO₂ has an established and growing presence in industrial and cold storage refrigeration, while A2Ls are primarily shaping the future of HVAC and light commercial systems.
Careful, application-specific evaluation—rather than broad generalization—is essential to selecting the most appropriate refrigerant for any given project.
Industrial Refrigeration Experts
Trusted by some of Ontario’s finest for over 20 years.
Speak With a Technician Today
.webp)